>

Logistics Warehouse Steel StructuresDesign · Fabrication · Installation

High racking, high turnover, strict fire zoning; stringent floor flatness and load requirements; loading canopies and docks often built in the same phase

Get a Logistics Warehouse solution

Turkey is in a customs union with the EU, so industrial goods follow the EU common external tariff, with additional customs duty (ACD) applied to some origins. Structural steel components are conformity assessed to EN 1090 and CE marked, and seismic design is mandatory under TBDY 2018, the Turkish building earthquake code issued in 2018. The 2023 Turkey–Syria earthquakes caused about USD 150 billion in damage — roughly 9% of GDP — and large-scale reconstruction is driving demand for steel industrial and warehouse buildings.

Compliance route: EN 1090 and CE marking

In Turkey, structural steel components are conformity assessed to EN 1090 (execution classes EXC1–EXC4) and CE marked, with standards and conformity handled by the Turkish Standards Institution (TSE). Seismic design is mandatory under TBDY 2018.

Structural design under high seismic risk

Turkey sits on active fault systems including the East Anatolian Fault, so seismic risk is high and reconstruction projects demand strict seismic performance. Steel is light and ductile, but the system and connections must follow TBDY 2018.

Logistics: China to Mersin / Ambarlı and other ports

Turkey’s main ports include Mersin, Ambarlı, İzmir, İskenderun, Samsun, Haydarpaşa and Bandırma. For the south-eastern reconstruction region, cargo can land at İskenderun or Mersin and move inland by road.

Frequently asked questions

Is EN 1090 required to export to Turkey?
Yes. Structural steel components in Turkey are conformity assessed to EN 1090 and CE marked, with factory production control (FPC) and a Declaration of Performance (DoP) required. We prepare documents for the project execution class (EXC) and align with TSE requirements.
Can you support post-earthquake reconstruction projects?
Yes. Turkey mandates TBDY 2018 for seismic design; we select ductile systems to that code and issue the calculations. Projects in the south-eastern reconstruction region can also land at Mersin or İskenderun and move inland by road.
How is duty calculated?
Turkey is in a customs union with the EU and applies the EU common external tariff to industrial goods, with additional customs duty (ACD) on some origins. The exact rate depends on the HS code, and we flag it at quotation stage.
Need a steel structure solution and quotation for this market?

Send the span, use, province and site conditions — we reply with an EN 1090 and TBDY 2018 compliant solution and budget price within 48 hours.

Enquire now Browse all products