Logistics Warehouse Steel StructuresDesign · Fabrication · Installation

High racking, high turnover, strict fire zoning; stringent floor flatness and load requirements; loading canopies and docks often built in the same phase

Get a Logistics Warehouse solution

Germany is the core industrial market of the EU and a major destination for Chinese steel structure exports. Automotive, mechanical engineering, distribution and cold chain are the main sources of demand, while data centre construction around Frankfurt is growing fast. Germany is demanding on engineering quality and documentation: design follows DIN EN 1993, and components entering the market must be executed to EN 1090-1 with the corresponding marking and factory production control records.

Why EN 1090 execution class matters in Germany

Germany is a driving force behind the EN 1090 system, and clients and supervisors are strict about documentation. Logistics and commercial projects usually run EXC2, with EXC3 for long spans and public or critical structures. Beyond the execution class, clients often require welding organised to DIN EN ISO 3834 with material traceability and coating inspection records.

Codes and climate loads

Design follows DIN EN 1993 with German National Annexes and loads follow DIN EN 1991. Snow is heavier in the southern uplands while wind dominates in the north; industrial and coastal areas need a C3–C4 corrosion environment, with S235 / S355 steel commonly used.

Delivery and logistics: Shanghai / Ningbo to Hamburg, Bremerhaven

Detailing and fabrication take place at our Shanghai and Jiangsu facilities; knocked-down members ship from Shanghai or Ningbo to Hamburg and Bremerhaven with marking drawings, packing lists and erection guidance.

Frequently asked questions

Can you provide calculations to German standards?
Yes. We design to DIN EN 1993 with German National Annexes and issue calculations, connection details and welding documents; if review by a German engineer is required, we provide the original model and design input data.
How is the EXC class decided for German clients?
The execution class follows the structure use, consequence of failure and execution conditions — EXC2 for most logistics and commercial projects, EXC3 for critical structures. We confirm the class at quotation stage and organise production and documentation to it.
Who handles site erection?
We provide member marking, erection sequence drawings and remote technical support; site erection is normally carried out by a qualified German contractor, and we can send engineers to site to guide.
Need a steel structure solution and quotation for this market?

Send the span, use and site conditions — we reply with an EN 1090 solution and budget price within 48 hours.