Logistics Warehouse Steel StructuresDesign · Fabrication · Installation

High racking, high turnover, strict fire zoning; stringent floor flatness and load requirements; loading canopies and docks often built in the same phase

Get a Logistics Warehouse solution

Canada is the second largest steel structure market in North America, with warehousing and logistics, data centres, mining and agricultural facilities driving demand. Canada is vast and its climate harsh: ground snow loads exceed 3 kPa in some regions and winter temperatures can reach −40 °C, so low-temperature impact toughness and heavy snow design are the governing conditions; the west coast around Vancouver also needs seismic design. Entering Canada requires design and fabrication to the NBCC and CSA series standards.

The governing conditions: heavy snow and low temperature

Snow loads across most of Canada are significantly higher than in comparable Chinese climate zones, so roof purlins, roof sheeting and drainage must be strengthened for local snow and drifting conditions; cold regions have clear requirements for steel low-temperature impact toughness, so grades must suit the project minimum design temperature. Steel's light weight and short programme are a clear advantage given Canada's limited winter construction window.

CSA codes and welding certification

Design follows NBCC and CSA S16 (steel structures), cold-formed members follow CSA S136 and welding follows CSA W59. Canada is strict on welding qualification (CSA W47.1 / W55.3 certification), so exported members are usually produced with a certified fabricator or inspected and documented to the client's requirements.

Delivery and logistics: Shanghai / Ningbo to Vancouver, Montreal

Detailing and fabrication take place at our Shanghai and Jiangsu facilities; knocked-down members ship from Shanghai or Ningbo to Vancouver and Montreal with marking drawings, packing lists, erection guidance and the relevant calculations.

Frequently asked questions

What does the Canadian cold require of the steel?
Cold regions set clear requirements for low-temperature impact toughness. We select grades and quality classes for the project minimum design temperature and apply suitable welding and bolting procedures for cold conditions to avoid brittle fracture risk.
Can you issue calculations to CSA standards?
Yes. We design to NBCC and CSA S16 and issue calculations, connection details and welding documents; where the client requires a CSA W47.1 certified fabricator, we confirm the compliant production and inspection route at project start.
Who handles site erection?
We provide member marking, erection sequence drawings and remote technical support; site erection is normally carried out by a qualified Canadian contractor, and we can send engineers to site to guide.