项目动态:电梯试验塔钢结构交付Project Update: Elevator Test Tower Delivered

项目动态 · Projects Xionglan Engineering Team

高 42m 的电梯试验塔,井道垂直度偏差控制在 8mm 以内,焊缝 100% 探伤。A 42m elevator test tower with shaft verticality held within 8mm — all welds ultrasonically tested.

电梯试验塔对钢结构的精度要求远高于普通厂房:井道是电梯导轨的安装基准,42m 高度范围内垂直度偏差需控制在 8mm 以内。

我们的做法:构件加工阶段按负公差控制焊接变形,井道立柱采用整体热浸镀锌;安装阶段每三层复测一次垂直度,用激光垂准仪校正,累计误差不过夜。

塔体同时承受试验电梯的冲击荷载,所有主要焊缝按一级焊缝 100% 探伤。项目已通过业主验收并投入使用。

特种钢构(试验塔、烟囱、火炬塔)看似体量小,实则是技术密度最高的品类之一,欢迎有此类需求的客户与我们交流。

An elevator test tower demands far higher steel accuracy than ordinary plants: the shaft is the datum for guide-rail installation, and verticality must stay within 8mm over 42 meters.

Our approach: control welding deformation to negative tolerances during fabrication, hot-dip galvanize the shaft columns, and re-survey verticality every three levels during erection with a laser plumb instrument — no accumulated error left overnight.

The tower also takes impact loads from test elevators, so all primary welds are Class 1 with 100% UT. The project has passed acceptance and is in service.

Special structures — test towers, stacks, flare stacks — look small but are among the most technically dense categories. Clients with such needs are welcome to talk to us.

电梯试验塔特种钢结构elevator test towerspecial steel structure
需要钢结构方案与报价?/ Need a steel structure quote?

上海雄岚钢结构 · 出口 60+ 国家 · EN 1090 CE 认证 · 24 小时内工程师回复

联系工程师 / Talk to an engineer 查看产品体系